Three-Phase 3kVA-500kVA Variable Frequency Power Supply 3∅ 4W+G IGBT/PWM DPF-33400

Product Details
Customization: Available
Application: High Frequency Converter Transducer
Output Type: Triple
Manufacturer/Factory & Trading Company
Gold Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (26)
  • Three-Phase 3kVA-500kVA Variable Frequency Power Supply 3∅ 4W+G IGBT/PWM DPF-33400
  • Three-Phase 3kVA-500kVA Variable Frequency Power Supply 3∅ 4W+G IGBT/PWM DPF-33400
  • Three-Phase 3kVA-500kVA Variable Frequency Power Supply 3∅ 4W+G IGBT/PWM DPF-33400
  • Three-Phase 3kVA-500kVA Variable Frequency Power Supply 3∅ 4W+G IGBT/PWM DPF-33400
  • Three-Phase 3kVA-500kVA Variable Frequency Power Supply 3∅ 4W+G IGBT/PWM DPF-33400
  • Three-Phase 3kVA-500kVA Variable Frequency Power Supply 3∅ 4W+G IGBT/PWM DPF-33400
Find Similar Products

Basic Info.

Model NO.
DPF-33400
Switch Mode
IGBT or PWM
Main Circuit Type
Voltage
Voltage of Power Supply
High Voltage Variable-Frequency Drive
Link of Transformation
AC-DC-AC Variable-Frequency Drive
Nature of DC Power
Voltage Variable-Frequency Drive
Function
Provide Continuous,Pure,Stable Sinusoidal Voltage
Brand
Wenlida
Output Frequency
25-1000Hz Continuously Adjustable
Input Frequency
0-1000V Continuously Adjustable
Voltage Regulating Mode
PWM or IGBT
Load Stability Rate
≤±1%(Pure Resistive Load)
Frequency Stability Rate
≤±0.01%
Distortion Rate
Thd≤±2%(Pure Resistive Load)
Peak Factor Ratio
3:1
Efficiency
≥85%
Reaction Time
≤2ms
Isolation Resistance
500VDC/200mΩ
Stand Voltage Insulation
1800VAC/5mA/1min
Cooling Mode
Forced Fan Cooling
Noise
Less Than 60dB at 1m
Transport Package
Wooden Case
Trademark
WENLIDA
Origin
China
HS Code
85044019
Production Capacity
20000PCS/M

Product Description

PRODUCT INTRODUCTION:
        DP series frequency power supply of WENLIDA is high efficient and advanced AC simulated power supply. It can provide not only continuous, clear and stable sinuous voltage, but also automatic power transferring function in case of over temperature, over load and over voltage. Through IGBT/PWM mode, this power supply can output sinuous wave with high stability and low disturbance. Further more, it is designed with independent 3-phase circuit for the great imbalanced load capacity. Frequency output by the bit control, reasonable heat spreading system, wide range of output voltage, and high capacity utilization. The series products are good appearance and elegant, high precious digit indication, humanized operation panel and simplified program.

MAIN TECHNICAL SPECIFICATIONS:
Phase TYPE Rated Capacity
(KVA)
Phase number Circuit mode Voltage
(V)
Current
(A)
Size(mm)
Width*Height*Depth
Weight(kg)
High Low



Single

 
DPF-500W 0.5 1∅2W+G Transistor amplification mode

220V±15%
50Hz/
60Hz±3Hz



 
2 4 430*540*200 25
DPF-11001 1 4 8 30
DPF-11002 2 IGBT/PWM


 
8 16 430*540*700 50
DPF-11003 3 12 24 75
DPF-11005 5 20 40 85
DPF-11010 10 42 84 430*770*990 145
DPF-11015 15 63 126 165
DPF-11020 20 83 166 195
DPF-31010 10 3∅4W+G 220/
380V±15%
50Hz/
60Hz±3Hz
42 84 155
DPF-31015 15 63 126 185
DPF-31020 20 83 166 275
DPF-31030 30 125 250 600*970*1240 345
DPF-31045 45 187 374 450
DPF-31060 60 250 500 800*1090*1600 580
DPF-31075 75 312 624 620
DPF-31100 100 417 834 820
DPF-31125 125 521 1042 1200*1100*1600 930
DPF-31150 150 625 1250 1200
Three DPF-33003 3 220/
380V±15%
4 8 430*770*900 120
DPF-33006 6 8 16 150
DPF-33010 10 13 26 175
DPF-33015 15 20 40 600*970*1240 300
DPF-33020 20 27 54 345
DPF-33030 30 41 82 385
DPF-33045 45 62 124 800*1090*1600 528
DPF-33060 60 83 166 635
DPF-33070 75 104 208 700
DPF-33100 100 138 276 1000
DPF-33150 150 208 416 1200*1100*1600 1400
DPF-33200 200 277 554 1900
DPF-33250 250 374 694 2000*1400*2000 2400
DPF-33300 300 416 832 3000
DPF-33400 400 555 1110 3000*1400*2000 3600
DPF-33500 500 694 1388 4000
Output phase voltage HIGH:10~300V   LOW:5~150V
Output phase voltage 50Hz ,60Hz,40~70Hz Continuously adjustable
(100Hz, 120Hz, 200Hz, 240Hz, 400Hz optional)
Load stability rate ≤±1%(Pure resistive load)
Frequency stability rate ≤±0.01%
Distortion rate THD≤±2%(Pure resistive load)
Peak factor ratio 3:1
Efficiency ≥85%
Reaction time ≤2ms
Display accuracy Resolution 0.1V, voltmeter, ammeter, frequency meter 4.5 digit digital display (optional power meter)
Overload capacity 120% delay 600s, 150% delay 60s, 200% delay 1s
Protection function Over current protection, short circuit protection, over voltage protection, over temperature protection, self diagnosis protection and alarm device
ontrol function (optional) Remote control less than 30m, convenient for remote control of voltage, frequency, switching machine and other RS-485 / RS-232 / GPIB interface and control software
Protection level IP30 or customized to meet the three defense requirements
Isolation Resistance 500VDC/200MΩ
Stand voltage insulation 1800VAC/5mA/1min
Cooling mode Forced fan cooling
Noise Less than 60dB at 1m

FUNCATIONAL FEATURES:         
1. Strong overload capacity: it has 300% overload capacity to meet the starting requirements of impact load; 
2. Slow start function: reduce the starting current of transformer, compressor and motor to realize the slow start of load and reduce the requirement of power capacity;         
3. Wide output range: the output frequency can be continuously adjustable from 25Hz to 1000Hz, and the output voltage can be continuously adjustable from 0 to 1000V; 
4. Low harmonic interference: output sinusoidal waveform, full load distortion less than 1.5%, low radiation interference, does not affect the use of the surrounding;           
5. Strong protection function: with overload, output short circuit, input open circuit, over temperature, over voltage, over frequency, under frequency, output phase sequence, back EMF, self diagnosis protection and alarm devices.


USING CONDITIONS:          
1. Working temperature: 0 ºC ~ 45 ºC            
2. Altitude: 1500m            
3. Relative humidity: 0-90% (non condensing state)            
4. The installation site shall be free of gas, steam, chemical deposition, dust, dirt and other explosive and corrosive media that seriously affect the insulation of the pressurizer;            
5. The installation site shall be free from serious vibration or turbulence            
6. Any special use conditions that do not meet the above provisions shall be determined by the user and our factory through negotiation

 

Three-Phase 3kVA-500kVA Variable Frequency Power Supply 3∅ 4W+G IGBT/PWM DPF-33400
Three-Phase 3kVA-500kVA Variable Frequency Power Supply 3∅ 4W+G IGBT/PWM DPF-33400































 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
People who viewed this also viewed