Customization: | Available |
---|---|
Current Type: | AC |
Phase: | Three Phase |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Item No. | Item Name | Item Description |
1 | INPUT VOLTAGE (V) | 380V +/- 20% |
2 | WORKING FREQUENCY (Hz) | 50 / 60Hz |
3 | REGULATION MODE | Independent phase regulation |
4 | CONSTANT VOLTAGE PRECISION | +/- (1~5%) adjustable |
5 | NOISE (dB) | 55 dB |
6 | INSULATION CLASS | F |
7 | OPERATION TIME (hr) | ≥ 100,000 hours |
8 | PROTECTION CLASS | IP 20 |
9 | VOLTAGE WITHSTANDING | 2000V, 1min. Not broken |
10 | WAVE DEFORMATION / DISTORTION | ≤ 0.1% |
11 | EFFICIENCY | ≥ 98% |
12 | INSULATION RESISTANCE (MΩ) | ≥ 2MΩ |
13 | RESPONSE TIME (ms) | ≤ 100ms |
14 | TIME FOR STABILIZING | When the input voltage jumps 10% relative to the rated value, the stabilizing time is less than 1.5s. |
15 | PACKING | Plywood packing |
16 | ELECTRICAL SAFETY | CE |
17 | ALTITUDE (m) | < 2000m |
18 | RELATIVE HUMIDITY | < 90% |
19 | AMBIENT TEMPERATURE (ºC) | -15ºC to +45ºC |
20 | COOLING METHOD | Forced air cooling with fan |
21 | ANTI-SURGE PERFORMANCE | The input terminal is equipped with a high-energy surge impulse suppressor, which effectively solves the fatal impact of the pulse spike voltage between 10μs and 100μs, such as lightning induction in the equipment. |
Item No. | Function Name | Item Description |
1 | OVER-VOLTAGE & UNDER-VOLTAGE PROTECTION | When output voltage is over or under rated voltage value, the equipment will automatically trip. |
2 | OVER-CURRENT PROTECTION | When the over-current exceeds the rated value, the input will be cut-off automatically. |
3 | MECHANICAL PROTECTION & OVERLOAD PROTECTION | When the regulating voltage operation exceeds the region, the adjustment will be automatically terminated. Once overload, it will automatically cut-off the power. |
4 | Overload is at 130% with 1 min. | |
5 | SHORT CIRCUIT PROTECTION | When the load is short circuit, it will automatically cut-off the power supply. |
6 | BYPASS FUNCTION | It can be manually switched to mains supply during the maintenance. |
7 | RETURN FUNCTION | When the sampling voltage exceeds the set value, the supplied voltage automatically returns to normal. |
8 | DISPLAY FUNCTION | LCD Display |
9 | PHASE PROTECTION | When phase sequence is reserve or less, it will automatically be protected. |
10 | TRUE EFFECTIVE VALUE SAMPLING | High accuracy |
11 | Good sensitivity | |
12 | Good measurement rate | |
13 | FREQUENCY CHARACTERISTICS | High input impedance |
14 | Low output impedance | |
15 | Wide power supply range | |
16 | Low power consumption | |
17 | VACUUM DIPPING PAINT | High insulation strength |
18 | Good mechanical properties | |
19 | Low noise | |
20 | Corrosion resistance | |
21 | Long service life | |
22 | CONTROL CHIP | The MCU control chip adopts the original imported ARM chip which is the industrial grade, 32-bit interface, and STM micro-electronics. |
23 | Advantages: | |
24 | Strong anti-interference precision AD acquisition. | |
25 | Digital circuit control. | |
26 | Reliable. | |
27 | Intelligent operation. | |
28 | DIMENSIONS (width * depth * height) mm |
850*700*1320 ~ 1800*1100*2200 |
29 | WEIGHT (kg) | 200kg ~ 3600kg |
CAPACITY(kVA) |
ENCLOSURE DIMENSION
(W*D*H)mm
|
CABINET(s) |
20 | 850*700*1320 | 1 |
30 | ||
50 | ||
80 | 860*750*1500 | 1 |
100 | ||
120 | ||
150 | 1050*850*1850 | 1 |
180 | ||
225 | ||
320 | 1350*1100*2200 | 1 |
400 | ||
500 | Primary cabinet: 1400*850*2200 Secondary cabinet: 1200*850*2200 |
2 |
600 | ||
800 | Primary cabinet: 1400*850*2200 Secondary cabinet: 1300*850*2200 |
2 |
1000 | ||
1200 | Primary cabinet: 1750*800*2200 Secondary cabinet: 800*800*2200 |
2 |
1400 | ||
1600 | Primary cabinet: 1800*1050*2200 Secondary cabinet: 1000*1050*2200 |
2 |
1800 | ||
2000 | Primary cabinet: 1800*1100*2200 Secondary cabinet: 1600*1100*2200 |
2 |
2400 |